Critical infrastructure cooling
Precision air conditioners
Equipment for maintaining a stable microclimate in server rooms, data centers and telecommunications nodes with high accuracy of temperature and humidity.

- Round-the-clock operationDesigned for continuous 24/7 operation without loss of performance.
- High precisionMaintaining temperature and humidity with minimal deviations.
- Redundancy capabilityN+1 schemes ensure uninterrupted operation in the event of failure of one of the modules.
- Variety of designsCabinet, in-row, in-cabinet; bottom or top air supply.
- Integration into control systemsConnection to dispatching and monitoring.
- Long service lifeIndustrial components and thoughtful design.
Application features
Why precision air conditioners are needed
Server rooms and data centers (DCs) are a key link in business processes. For stable operation of computing equipment, efficient cooling is required, which household or semi-industrial air conditioners cannot provide.
Precision air conditioners are specifically designed to remove large heat loads while maintaining low temperature (e.g., 22±1 °C) and specified humidity. They take into account not only room parameters but also the heat load from equipment, as well as redundancy requirements.
The choice of a specific model depends on several factors: heat removal method (air or water), air supply direction, design type, and redundancy level. Each configuration is offered already at the design stage of the facility.
Areas of application
Where precision air conditioners are used
The equipment is in demand at facilities with critical electronics and high requirements for microclimate.

- 01Data centers (DC)Ensuring stable temperature and humidity in data centers with high heat density.
- 02Server roomsRound-the-clock cooling of servers, switches, and data storage systems.
- 03Telecommunication communication nodesMaintaining operating conditions of active communication equipment.
- 04Dispatch and operator roomsCreating a comfortable microclimate for personnel and protecting electronics.
Types and configurations
What are precision air conditioners like?
Various cooling methods, air supply, and design solutions allow you to choose the optimal system for a specific facility.
Air-cooled
Heat is removed through an outdoor condenser installed outside the building. The most common solution for server and telecommunications facilities.
Water-cooled
Heat is transferred to the building's water circuit. Used in large facilities with advanced engineering infrastructure.
Underfloor air supply
Cooled air is delivered through a raised floor directly to the equipment. Often used in modern data centers to create directional airflow.
Overhead air supply
Air is distributed through ducts or directly into the room from above. Suitable for facilities without a raised floor.
Cabinet (perimeter)
Classic standalone design for perimeter cooling. A universal solution for most facilities.
Inter-row (InRow)
Installed between server racks. Provide localized spot cooling of hot zones in data centers with high heat density.
Rack-mounted (in-cabinet)
Compact systems mounted directly inside the server cabinet for cooling at heat sources.
By redundancy level
Single systems for basic requirements or N+1 redundant for continuous operation in case of one air conditioner failure.
Selection stages
How precision air conditioners are selected
The selection is based on the analysis of heat emissions, room parameters, and reliability requirements.
01
Calculation of thermal load
The total heat emission of server equipment is determined, as well as heat gains from walls, lighting, and personnel.
02
Selection of cooling method
Air or water cooling is selected based on the availability of space for an outdoor condenser or the possibility of connecting to a water circuit.
03
Configuration definition
The air supply direction (bottom/top) and design type (cabinet, in-row, in-cabinet) are selected.
04
Redundancy calculation
For critical facilities, an N+1 scheme is used to ensure uninterrupted operation in the event of failure of one of the modules.

Advantages
Why choose precision air conditioners
Specialized equipment provides reliable protection for expensive computing equipment.
01
High precision in maintaining temperature and humidity
Allows compliance with strict microclimate requirements for server rooms and data centers.
02
24/7 operation
The equipment is designed for continuous operation without interruptions.
03
High reliability
Industrial components and thoughtful design minimize the risk of failures.
04
Redundancy capability
Hot standby schemes guarantee preservation of cooling in case of emergency.
05
Integration into dispatch systems
Support for BMS protocols allows remote monitoring of parameters.
06
Long service life
The service life is significantly higher than that of household air conditioners.
07
Protection of critical equipment
Preventing overheating and failure of servers, switches, data storage systems.
Selection criteria
What to consider when selecting
Proper selection of equipment requires consideration of many factors. Our engineers will help you at all stages.
- Heat dissipation of installed equipment
- Room dimensions and layout
- Server rack layout diagram
- Presence of raised floor (for bottom air supply)
- Redundancy requirements (N+1, 2N, etc.)
- Possibility of installing an outdoor condenser or connecting to a water circuit
- Operating conditions (outdoor air temperature, year-round operation mode)

Service and support
Help from Klimatrade
We support design organizations and installation companies at all stages of working with the project.
- Selection of equipment for project tasks
- Technical consultations on types and configurations
- Assistance to designers and engineers
- Preparation of technical and commercial proposals
- Technical support at the project implementation stage
- Scheduled technical maintenance (recommended at least 2 times per year)
Buy a precision air conditioner for a server room or data center
If you need stable server room air conditioning, server room cooling or data center cooling, Klimatrade specialists will help you select equipment according to your facility parameters. A precision air conditioner for a server room, a server room air conditioner and a data center air conditioner ensure accurate temperature control and are suitable for 24/7 operation.
We supply precision air conditioners in Kazakhstan for server rooms, telecommunications rooms, data centers and industrial facilities. If you are planning to buy a precision air conditioner, submit a request — we will select a precision air conditioner, calculate the required capacity and choose the optimal operating scheme.
The precision air conditioner price depends on the heat load, room area, number of racks, operating mode and requirements for server room air conditioning redundancy. For each project, we select an industrial air conditioner for a server room and other climate equipment for data centers.
Precision air conditioners are available for Almaty, Astana and other regions of Kazakhstan. Submit a request — we will select a precision air conditioner for a data center or server room and prepare a commercial offer for your facility.
Frequently asked questions
FAQ
Answers to the most common questions about precision air conditioners.
How is a precision air conditioner different from a regular one?
Precision systems are designed for round-the-clock operation and provide significantly more accurate temperature and humidity control.
Where are precision air conditioners most often used?
In server rooms, data centers, telecommunications nodes, and other rooms with critical equipment.
Is a backup air conditioner needed?
For most server rooms and data centers, redundancy is recommended, and for critical facilities it is a mandatory requirement.
Do precision air conditioners operate in winter?
Yes. They are designed for year-round operation and are able to effectively dissipate heat even at negative outdoor temperatures.
How to choose the equipment power?
Selection is based on equipment heat dissipation, room size, rack layout, and redundancy requirements.
How often is maintenance required?
It is recommended to carry out scheduled technical maintenance at least twice a year, and for high-load facilities — according to the operating regulations.
Ready for the project?
Selection of a precision air conditioner for your task
Leave a request — our specialists will help you choose the optimal solution taking into account heat emissions, room configuration, and redundancy requirements.